What 21 CFR 211.67 requires

  • Equipment and utensils must be cleaned, maintained and, where the product needs it, sanitized or sterilized at suitable intervals to prevent malfunctions or contamination.
  • There must be written procedures for cleaning and maintenance, including who is responsible, schedules, methods, materials, how to protect clean equipment and how to inspect it before use.
  • Records of cleaning and maintenance must be kept.

Read the official text on eCFR (21 CFR 211.67).

What gets cited under 211.67

Patterns that commonly appear in Form 483 observations and warning letters citing this section:

  • Cleaning procedures did not say how to disassemble equipment, which agents to use or how long clean equipment can sit before use.
  • No evidence that cleaning works (no validation, or validation that did not cover the hardest-to-clean product or worst-case equipment).
  • Residue, product build-up or moisture was found on equipment labelled clean.
  • Preventive maintenance was overdue, or repairs were done without assessing impact on product.

Questions to ask before an investigator does

  • Is there a clean hold time and a dirty hold time, and are they supported by data?
  • Does cleaning validation cover worst-case products, equipment and surfaces?
  • Can a new operator follow the procedure step by step without asking anyone?

Common root causes

  • Cleaning steps live in operators' heads, not in the procedure.
  • Product mix changed and cleaning validation was never revisited.
  • Maintenance and quality do not share the same work-order view.

What a solid corrective and preventive action plan includes

  1. Rewrite cleaning procedures with disassembly steps, agents, concentrations, times and visual-inspection criteria.
  2. Run a worst-case cleaning validation (or re-validation) with swab and rinse limits you can defend.
  3. Set and verify clean and dirty hold times.
  4. Link maintenance work orders to quality impact assessment.
  5. Check effectiveness by trending swab results and visual inspection failures.

If your 483 cites 211.67

A written response within 15 business days of the inspection close-out is voluntary, but FDA considers responses received in that window before deciding on further action, such as a warning letter. Address each observation: what you found, the root cause, the correction, the preventive action, the evidence, and dates. Avoid blaming individuals without asking why the system allowed the error.

Paste your observations into the free Form 483 triage tool to get each one mapped to FDA's inspection systems with a response calendar, or see how Claraxis helps with 483 responses.

← 21 CFR 211.25All sections21 CFR 211.68 →

Plain-language summary written by Claraxis Group to help teams prepare; not legal advice and not the regulation itself. Requirements are paraphrased from 21 CFR Part 211; always work from the official text and current FDA guidance.

Book a call